Specifications
Battery Type | 9 volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cells |
---|---|
Battery Capacity | Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003) |
Install-by Date | Battery is labeled with an install-by date of at least five years from date of manufacture |
Standby Life | Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified Standby Temperature range, assuming one battery insertion test and no defibrillation uses) |
Waveform | SMART Truncated exponential biphasic. Waveform parameters adjusted as a function of patient impedance |
Defibrillation peak current - Adult | 32 A (150 J nominal) into a 50 ohm load |
Defibrillation peak current - Pediatric | 19 A (50 J nominal) into a 50 ohm load (using optional infant/child SMART Pads Cartridge) |
Quick Shock | Able to deliver a shock after the end of a CPR interval, typically in eight seconds |
Shock-to-Shock Cycle Time | Typically less than 20 seconds between shocks in a series |
Voice Instructions | Detailed voice messages guide responder through use of the defibrillator |
CPR Guidance | Instructions for adult and infant/child CPR available at user selection |
Shock Delivery | Via adhesive pads placed on patient's bare skin as illustrated on pads |
Controls | Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock button |
Indicators | Ready light, blue i-button, caution light |
Energy delivered | Adult: nominal 150 joules into a 50 ohm load; Infant/Child: nominal 50 joules into a 50 ohm load |
How Supplied | Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution |
Active Surface Area | 85 cm² (13.2 in²) each |
Cable Length | Adult pads: 137 cm (54"); Infant/Child pads: 102 cm (40") |
Use-by Date | Cartridge is labeled with a use-by date of at least two years from date of manufacture |
Daily Automatic Self-tests | Tests internal circuitry, waveform delivery system, pads cartridge, and battery capacity |
Pads Integrity Test | Specifically tests readiness-for-use of pads (gel moisture) |
Battery Insertion Test | Upon battery insertion, extensive automatic self-tests and user-interactive tests check device readiness |
Status Indicator | Blinking green "Ready" light indicates ready for use. Audible "chirp" indicates need for maintenance |
Infrared | Wireless transmission of event data to a PC or Palm PDA, using the IrDA protocol |
Data Stored | First 15 minutes of ECG and the entire incident's events and analysis decisions |
Sealing | Solid objects per EN60529 class IP2X; Drip-proof per EN60529 class IPX1 |
Operating Temperature | 0 - 50 °C (32 - 122 °F) |
Operating Altitude | 0 to 4,500 m (0 to 15,000 ft) |
Standby Temperature | 0 - 43 °C (32 - 109 °F) |
Operating Humidity | 0 to 95 % relative humidity (non-condensing) |
Shock/Drop Abuse Tolerance | Withstands 1 meter drop to any edge, corner, or surface |
Standby Humidity | 0 to 75 % relative humidity (non-condensing) |
Vibration | Meets EN1789 random and swept sine, road ambulance specification in operating and standby states |
Standby Altitude | > 48 hours from 0 to 8,500 ft and <48 hours from 8,500 to 15,000 ft |
EMI (Radiated/Immunity) | Meets EN55011 Group 1 Level B Class B and EN61000-4-3 |